Custom Air EquipmentAn HSM Company

Series FAfan arrays

Fan arrays that keep running

Two to thirty-six direct-drive plenum fans working as one. Lose a fan and the rest pick up the load. No belts, no sheaves, and a shorter, quieter fan section.

Nine direct-drive plenum fans arranged as a fan array

001at a glance

Specifications

Typical ranges. Every unit is selected for its project, and the submittal is the final word.

Fans per array
2 to 36
Motors
EC or PM, direct drive
Redundancy
N+1 standard, N+2 available
Isolation
Backdraft dampers or blank-off plates
Retrofit
Fits through a 36 in. door

002details

Redundancy you can size

An array is selected so the remaining fans still deliver design airflow with one fan out of service. For critical spaces we size for N+2.

  • N+1 standard, N+2 available
  • Backdraft dampers or blank-off plates for each fan
  • Fans swap out while the unit runs
  • Even velocity profile across the coil
Nine direct-drive plenum fans arranged as a fan array

003details

Direct drive with EC or PM motors

Each fan is driven directly by an EC motor or a PM motor on a VFD, so there are no belts to tension, replace or shed dust into the airstream.

  • High part-load efficiency
  • Speed control on every fan
  • Lower vibration and bearing wear
  • Simple spare parts list
Air handler connected to an airflow test duct in the factory test cell

004details

Built to fit through a door

Individual fan cubes are small enough to pass through a standard door, which makes fan arrays the usual answer for replacing an old single-fan unit in place.

  • Retrofit inside existing casings
  • Shorter fan section than a single large fan
  • Lower discharge sound in the low bands
  • Phased change-out in occupied buildings
Technicians reassembling a knockdown air handler in a basement mechanical room

Questions engineers ask about fan arrays

How many fans should an array have?

Enough that losing one still meets design airflow at an acceptable speed, balanced against motor efficiency and cost. We show the trade-off on the selection.

Can a fan array replace the fan in an existing air handler?

Usually, yes. Fan cubes are sized to pass through the existing access door and mount on a new bulkhead.

Do fan arrays use more energy than one large fan?

Not necessarily. At part load, many small direct-drive fans often beat one belt-driven fan because belt losses disappear.

Ready to build the unit your project actually needs?

Send a schedule, a drawing or a photo of the unit you are replacing. An application engineer calls back within one business day.