25 guidesengineering guides
Laboratories, Cleanrooms and Pharma
Air handling for laboratories, cleanrooms, containment and GMP pharmaceutical facilities.
explainers
- Laboratory Ventilation Under ANSI/ASSP Z9.5Explains Z9.5 requirements for lab exhaust, hoods and pressure; lab exhaust stack design is separate.
- Setting Laboratory Air Change RatesExplains how lab ACH is set from risk assessment rather than fixed rules; energy reduction strategies are separate.
- ISO 14644 Cleanroom Classes ExplainedExplains ISO 14644-1 classes, particle limits and FS 209E equivalents; airflow calculation is separate.
- GMP Pharmaceutical AHU Design PrinciplesExplains EU GMP Annex 1, FDA and Health Canada expectations for AHU design; validation steps are separate.
- Bag-In/Bag-Out Filter Housings for Contaminated ExhaustExplains BIBO housings, change-out procedure and testing ports; does not cover HEPA classes.
- Vivarium and Animal Facility Air HandlingExplains ACH, temperature stability and redundancy for animal housing; does not cover BSL containment.
- Pharmaceutical AHU Qualification: IQ, OQ and PQExplains qualification stages and documentation for GMP air handlers; general commissioning is in installation.
- Lab Exhaust Fans and High-Plume Stack DesignExplains induced-flow fans, stack height and re-entrainment per Z9.5; general intake siting is in filtration.
- Makeup Air Units for Semiconductor FabsExplains tight dew point, chemical filtration and large-volume MAU needs in fabs; does not cover pharma cleanrooms.
how tos
- How to Supply Makeup Air for Fume Hood ExhaustSteps to match makeup air to hood exhaust with VAV hoods and cross-drafts; hood diversity sizing is a separate calculation.
- How to Reduce Laboratory HVAC EnergySteps including ACH reduction, VAV hoods and recovery for labs; lab exhaust recovery details are in energy recovery.
- How to Design a Cleanroom Pressure CascadeSteps for setting differential pressures between ISO grades and airlocks; airflow calculation is separate.
- How HEPA Filter Integrity Testing Is PerformedSteps for PAO/DOP aerosol challenge scan tests and acceptance; does not explain HEPA classes.
calculations
- Calculating Cleanroom Airflow and Air Change RatesCalculates recirculation and outdoor airflow for ISO classes from ACH or velocity; does not cover pressure cascade.
- Sizing Lab Makeup Air Units for Fume Hood DiversityCalculates design airflow using hood usage diversity factors; does not cover makeup air control.
checklists
- BSL-3 Containment AHU Design ChecklistChecklist of exhaust redundancy, sealing, pressure and decontamination items for BSL-3 suites; damper specification is separate.
- Cleanroom AHU Design ChecklistChecklist of filtration, pressure, tolerance, materials and redundancy items for cleanroom AHUs; does not cover validation.
comparisons
- Fan Filter Units vs Central AHU Recirculation for CleanroomsCompares FFU ceilings with centralized recirculation AHUs on energy, noise and redundancy; does not compare once-through designs.
- Recirculating vs Once-Through Cleanroom Air SystemsCompares recirculation and 100% outdoor air approaches for cleanrooms and potent compounds; FFU comparison is separate.
- Stainless vs Painted Interiors for GMP Air HandlersCompares interior materials and finishes for cleanability and validation; general casing materials are in casing.
troubleshootings
- Troubleshooting Cleanroom Temperature and Humidity ExcursionsDiagnoses out-of-tolerance events from coil, reheat and control causes; particle failures are separate.
- Troubleshooting Laboratory Pressurization ProblemsDiagnoses lab pressure reversals from hood, valve and makeup air issues; hospital room pressure issues are in healthcare.
- Troubleshooting Cleanroom Particle Count FailuresDiagnoses HEPA leaks, airflow patterns and pressure issues behind failed counts; temperature excursions are separate.
spec guides
- Specifying Bubble-Tight Isolation Dampers for ContainmentHow to specify leak-tight dampers and test pressures for decontamination and isolation; AMCA leakage classes are in codes.
- Writing a Laboratory AHU SpecificationWhat to specify for 100% OA lab units, redundancy, coatings and controls; does not cover exhaust fans.
Ready to build the unit your project actually needs?
Send a schedule, a drawing or a photo of the unit you are replacing. An application engineer calls back within one business day.