Healthcare Facilities
Air handling for hospitals, surgery, isolation rooms and other healthcare spaces under ASHRAE 170 and CSA Z317.2.
explainers
- ASHRAE 170 Ventilation Requirements for Health Care FacilitiesExplains the Standard 170 space table for air changes, pressure, filtration and humidity; Canadian CSA Z317.2 comparison is separate.
- Airborne Infection Isolation Room Air HandlingExplains negative pressure, exhaust and anteroom requirements for AIIR; protective environment rooms are separate.
- Redundancy Requirements for Hospital AHUsExplains code and owner redundancy expectations for critical healthcare AHUs; fan array N+1 sizing is in fans.
- USP 797 and 800 Compounding Pharmacy Air HandlingExplains ISO class, pressure and air change requirements for sterile and hazardous compounding; industrial pharma GMP is in labs and pharma.
- Humidification Requirements for HospitalsExplains why healthcare favours steam humidification and chemical-free steam requirements; general humidifier types are in humidity control.
- Air Handling for Sterile Processing and DecontaminationExplains pressure, ACH and humidity requirements for SPD areas; ORs are separate.
- Protective Environment Room Air HandlingExplains positive pressure, HEPA supply and sealing for immunocompromised patient rooms; AIIR rooms are separate.
- Operating Room Unoccupied TurndownExplains Standard 170 provisions for reduced OR airflow when unoccupied while maintaining pressure; does not cover general building setback.
- Air Handling for Ambulatory Surgery CentersExplains how outpatient surgery centers differ from hospitals in AHU requirements; does not cover inpatient ORs.
- Ventilation for Long-Term Care and Senior LivingExplains ventilation, odour control and comfort needs for long-term care; does not cover acute care hospitals.
comparisons
- ASHRAE 170 vs CSA Z317.2 for Healthcare HVACCompares the US and Canadian healthcare HVAC standards on air changes, filtration and redundancy; does not cover OR design.
- Energy Recovery Options That Meet ASHRAE 170Compares runaround loops, plates, heat pipes and wheels for hospital exhaust under Standard 170 limits; general air class restrictions are in energy recovery.
how tos
- How to Design Air Handling for Operating RoomsSteps for OR airflow, laminar diffuser arrays, pressure and dedicated AHUs; low-temperature setpoints are separate.
- How to Achieve Low Operating Room Setpoints (60 F, 20% RH)Steps to reach low OR temperatures with dew point control and low-temperature chilled water; OR airflow design is separate.
- Replacing AHUs in Occupied Hospitals: ICRA MeasuresHow infection control risk assessment governs barriers, pressure and phasing during AHU work; general occupied-building replacement is in retrofit.
- How to Monitor Healthcare Room Pressure RelationshipsHow to select and locate room pressure monitors and alarms for AIIR, PE and OR; troubleshooting lost pressure is separate.
- How to Maintain Hospital AHUs Without ShutdownHow to plan isolation dampers, redundant fans and filter changes to service units while running; general PM schedules are in O&M.
spec guides
- Specifying ASHRAE 170 Filter Banks for Hospital AHUsHow to specify filter bank count, MERV levels and locations required by Standard 170; general filter selection is in filtration.
- Writing a Hospital AHU SpecificationWhat to specify for construction, redundancy, hygiene and testing in healthcare AHUs; filter banks are a separate spec guide.
calculations
- Calculating Hospital Room Airflow From Air Change RequirementsCalculates supply, outdoor and exhaust airflow from Standard 170 ACH values; pressure offsets are a separate calculation.
- Calculating Room Pressurization Airflow OffsetCalculates supply-exhaust offset from door gaps and target pressure differential; ACH-based airflow is a separate calculation.
checklists
- Essential Power Checklist for Hospital AHUsChecklist of NFPA 99, NFPA 110 and CSA Z32 essential electrical considerations for AHUs; does not cover redundancy of fans.
- Healthcare AHU Design ChecklistChecklist of redundancy, filtration, humidity, hygiene and access items for hospital AHUs; does not cover specification language.
troubleshootings
- Troubleshooting Operating Room Humidity ProblemsDiagnoses high or low OR humidity from coil, chilled water and control causes; low-setpoint design method is separate.
- Troubleshooting Loss of Room Pressurization in HospitalsDiagnoses lost negative or positive pressure from door, airflow and control issues; monitor selection is separate.