25 guidesengineering guides
Fans and Fan Arrays
Fan types, fan array design, fan performance and fan selection for custom air handlers.
comparisons
- Plenum Fan vs Housed Centrifugal Fan in AHUsCompares unhoused plenum fans and scrolled housed fans for efficiency, space and discharge flexibility; does not cover fan arrays.
- Fan Array Redundancy: N+1 vs N+2 SizingCompares redundancy levels and the airflow each fan must carry when one or two fail; does not cover controls response.
- Airfoil vs Backward Inclined vs Forward Curved Fan WheelsCompares centrifugal blade shapes for efficiency, stability and noise; does not cover axial or mixed-flow fans.
- Backdraft Dampers vs Blank-Off Plates in Fan ArraysCompares methods of preventing recirculation through a failed fan; does not cover redundancy sizing.
- Direct Drive vs Belt Drive FansCompares drive losses, maintenance and speed flexibility; belt and sheave selection is in motors.
explainers
- What Is a Fan Array? How Multiple Fans Work in ParallelExplains fan array concept, footprint and redundancy benefits; does not size redundancy or pick the number of fans.
- Fan Curves and System Curves: Finding the Operating PointExplains how fan and system curves intersect and shift with speed and dampers; does not cover parallel fan behaviour.
- System Effect: How Inlet and Outlet Conditions Rob Fan PerformanceExplains AMCA 201 system effect factors at fan inlets and outlets; does not cover fan curve basics.
- Using Fan Energy Index (FEI) to Compare Fan SelectionsExplains how FEI is calculated and used to compare selections at the duty point; code minimum FEI requirements are in codes.
- Fan Array Discharge Velocity Uniformity and Downstream SpacingExplains velocity profiles behind fan arrays and effects on coils and filters; plenum depth design is a separate how-to.
- Mixed-Flow and Axial Fans in Air Handling ApplicationsExplains where vaneaxial and mixed-flow fans fit in AHU and inline duty; industrial radial fans are covered in industrial.
- Fan Static Efficiency vs Total EfficiencyExplains the difference between static and total efficiency and why plenum fans report differently; does not cover FEI.
- Factory Fan Balance Grades: ISO 21940 G2.5 and G6.3Explains balance quality grades and what factory balancing achieves; field vibration limits are in acoustics.
- Inlet Cone Overlap and Wheel Clearance Effects on PerformanceExplains how cone gap and overlap affect efficiency and noise; does not cover inlet obstructions (system effect).
- Fans in Parallel and Series: System Curve BehaviourExplains combined curves for parallel and series fans including supply/return interaction; does not explain fan array benefits.
- Fan Wheel Materials and CoatingsExplains steel, aluminum, stainless and coated wheels and their limits; spark-resistant construction is in industrial.
calculations
- Applying the Fan Laws: Speed, Airflow, Pressure and PowerWorks fan law examples for speed and diameter changes; annual energy savings from VFDs are in motors.
- Calculating Fan Tip Speed and Maximum Class LimitsCalculates wheel tip speed and checks against AMCA 99 class limits; does not cover balancing.
- Calculating Fan Brake HorsepowerWorks the bhp equation with efficiency and density corrections; motor sizing margins are in motors.
troubleshootings
- Troubleshooting Fan Surge, Stall and Unstable OperationDiagnoses operation left of peak pressure and pulsation; general vibration diagnosis is in acoustics.
- Troubleshooting a Fan That Will Not Deliver Rated AirflowDiagnoses fan-level causes (rotation, wheel, speed, inlet effects) of low airflow; system-wide static issues are in operation and maintenance.
how tos
- How to Choose the Number and Size of Fans in an ArraySteps for selecting fan count and wheel size against cross-section, efficiency and redundancy; does not compare N+1 vs N+2.
- Measuring Fan Airflow With Inlet Piezometer RingsHow inlet cone flow taps work, calibration K-factors and accuracy; standalone outdoor air measuring stations are in controls.
- How to Set Fan Array Plenum Depth and Fan SpacingSteps to set fan-to-fan and fan-to-wall spacing and inlet/discharge plenum depth; does not cover velocity uniformity theory.
checklists
Ready to build the unit your project actually needs?
Send a schedule, a drawing or a photo of the unit you are replacing. An application engineer calls back within one business day.