Energy Recovery
Wheels, plates, runaround loops and heat pipes: performance, frost control, leakage and economics.
comparisons
- Wheels vs Plates vs Runaround Loops vs Heat PipesCompares the four main air-to-air recovery technologies on effectiveness, leakage and footprint; does not cover any one technology in depth.
- Enthalpy Wheel vs Sensible WheelCompares total and sensible-only wheels for latent transfer and frost behaviour; does not cover media materials.
- Crossflow vs Counterflow Plate Heat ExchangersCompares plate exchanger geometries for effectiveness, pressure drop and size; does not cover frost control.
- Wheel Media: Aluminum, Polymer and Desiccant CoatingsCompares wheel media materials for latent performance, cleanability and durability; does not compare wheel types.
how tos
- How to Design a Runaround Coil LoopSteps to size coils, pump, glycol and controls for a runaround loop; does not compare it with other technologies.
- Frost Control Strategies for Wheels and Plates in Cold ClimatesHow to apply preheat, bypass, speed modulation and defrost cycles in Canadian and northern US climates; frost threshold math is separate.
- Determining When ASHRAE 90.1 Requires Energy RecoveryHow to use 90.1 climate zone and outdoor air percentage tables to decide if recovery is mandatory; NECB is covered in codes.
- How to Place Fans to Minimize Recovery Device LeakageHow fan positions and pressure differentials control cross-leakage direction; does not define EATR.
- How to Run Energy Recovery During Economizer ModeHow wheel speed modulation and bypass dampers avoid unwanted recovery when free cooling; OA damper economizer logic is in controls.
- How to Add Energy Recovery to an Existing AHUSteps to evaluate space, duct proximity and fan capacity to add recovery to existing systems; general retrofit decisions are in retrofit.
explainers
- Heat Pipe Air-to-Air Heat RecoveryExplains side-by-side heat pipe exchangers between exhaust and supply; wraparound heat pipes for dehumidification are in humidity control.
- EATR and OACF: Understanding Wheel Leakage MetricsExplains exhaust air transfer ratio, outdoor air correction factor and purge sectors; fan placement strategy is a separate guide.
- AHRI 1060 Ratings for Air-to-Air Recovery ComponentsExplains what AHRI 1060 certifies and at which conditions; does not explain AHU-level ratings.
- Indirect Evaporative Precooling on the Exhaust Side of PlatesExplains wetting the exhaust side of a plate exchanger to precool outdoor air; dedicated data center IEC units are in data centers.
- Exhaust Air Classes and When Wheels Are Not AllowedExplains ASHRAE 62.1 air classes and contaminant concerns that restrict wheel use; healthcare-specific options are in healthcare.
- Dual-Wheel DOAS: Pairing an Enthalpy Wheel With a Sensible WheelExplains the dual-wheel arrangement that recovers energy and reheats air after the coil; standalone desiccant dehumidifiers are in humidity control.
- Recovering Heat From Industrial Process ExhaustExplains recovery from hot, dirty or corrosive process exhaust and suitable exchangers; HVAC-grade exhaust is covered elsewhere in this category.
calculations
- Calculating Energy Recovery Effectiveness and Leaving ConditionsCalculates sensible, latent and total effectiveness and leaving supply conditions; does not compute payback.
- Calculating the Frost Threshold Temperature for Recovery DevicesCalculates the outdoor temperature at which frosting begins from exhaust conditions; does not select a control strategy.
- Calculating Energy Recovery PaybackCalculates annual savings from bin data against first cost and fan penalty; does not compute effectiveness.
- Calculating the Fan Energy Penalty of Energy RecoveryCalculates added pressure drop and fan energy to net against recovered energy; payback is a separate guide.
troubleshootings
- Troubleshooting Wheel Drives, Belts and SealsDiagnoses stopped wheels, slipping belts and worn seals; low effectiveness diagnosis is separate.
- Diagnosing Low Energy Recovery EffectivenessDiagnoses fouling, bypass leakage, control faults and sensor errors behind poor recovery; mechanical wheel drive failures are separate.
- Troubleshooting Plate Exchanger Condensate and Drain ProblemsDiagnoses condensate overflow, ice blockage and drainage failures in plate exchangers; frost control strategy is separate.