25 guidesengineering guides
Controls and Sequences of Operation
Control sequences, sensors, protocols and tuning for air handling units.
explainers
- ASHRAE Guideline 36 High-Performance Sequences for AHUsExplains the structure and key AHU sequences in Guideline 36; writing a project-specific sequence is a separate how-to.
- Maintaining Minimum Outdoor Air in VAV SystemsExplains why fixed damper positions fail at low airflow and control alternatives; does not cover DCV.
- Low-Limit Freeze-Stat Sequences and SafetiesExplains freeze-stat wiring, reset logic and staged responses; coil freeze protection hardware is in coils.
- Fan Array Control Sequences: Speed, Staging and Failure ResponseExplains common speed control, staging fans off and response to fan failure; does not size redundancy.
- Optimal Start, Morning Warm-Up and Cool-DownExplains optimal start algorithms and warm-up modes with outdoor air closed; does not cover night purge.
- Unoccupied Setback and Night Purge SequencesExplains setback modes and night flush with cool outdoor air; does not cover optimal start.
- AHU Roles in Smoke Control and Fire ModesExplains shutdown, pressurization and smoke exhaust modes and firefighter override; detector and damper code rules are in codes.
- Automated Fault Detection and Diagnostics for AHUsExplains AFDD rule sets (e.g. G36 fault conditions) and data needs; does not troubleshoot specific faults.
- Dehumidification Mode Control SequencesExplains mode selection, coil dew point control and reheat staging logic; equipment comparisons are in humidity control.
how tos
- How to Implement Supply Air Temperature ResetSteps for trim-and-respond SAT reset and its humidity limits; static pressure reset is separate.
- How to Implement Duct Static Pressure ResetSteps for trim-and-respond static reset based on VAV damper position; does not cover fan array staging.
- How to Control Building Pressure With Return and Relief FansSteps for fan tracking, direct building pressure and relief control sequences; hardware arrangement choice is in fundamentals.
- How to Implement CO2 Demand-Controlled VentilationSteps for CO2 sensor placement, setpoints and reset of outdoor air; 62.1 calculation math is in filtration and IAQ.
- How to Tune PID Loops on Air HandlersSteps for tuning temperature, static and damper loops; diagnosing hunting in operation is separate.
- How to Select and Place Temperature and Pressure SensorsHow to place averaging, discharge, static and differential sensors in AHUs and ducts; humidity sensors are in humidity control.
- How to Write a Sequence of Operation for a Custom AHUSteps to write a clear, testable sequence including modes and alarms; does not explain Guideline 36 content.
comparisons
- Economizer High-Limit Controls: Fixed, Differential and EnthalpyCompares high-limit shutoff strategies by climate; code requirements for economizers are in codes.
- Outdoor Airflow Measurement: Thermal Dispersion vs Pitot vs Fan-BasedCompares OA measuring technologies for accuracy at low velocity; fan inlet piezometers are detailed in fans.
- BACnet vs Modbus for AHU Controls IntegrationCompares protocols for BAS integration of factory controls and EC motors; does not cover factory vs field controls.
- Factory-Mounted vs Field-Installed AHU ControlsCompares factory packaged controls with field controls for testing, warranty and coordination; does not cover protocols.
troubleshootings
- Troubleshooting Hunting and Oscillating Control LoopsDiagnoses oscillation from tuning, oversized valves and sensor location; tuning procedure is a separate how-to.
- Troubleshooting Economizer FaultsDiagnoses stuck dampers, bad sensors and wrong high-limit setup; general AFDD concepts are separate.
checklists
calculations