- Face Velocity Limits for Cooling Coils and Moisture CarryoverExplains why wet coils are limited to roughly 500 fpm and how fin type affects carryover; does not size the unit cross-section.
- DX Coil Circuiting, Face Split and Row SplitExplains refrigerant circuiting options and how they affect capacity staging; low-GWP refrigerant impacts are a separate guide.
- Coil Freeze Protection MethodsExplains glycol, pumped coils, integral face and bypass and preheat strategies against freezing; freeze-stat sequences are in controls.
- Coil Coatings for Corrosion ProtectionExplains e-coat, phenolic and other coil coatings and their capacity impact; casing coatings are in casing.
- AHRI 410 Coil Ratings: What Certification CoversExplains the AHRI 410 rating standard for forced-circulation coils and its limits; does not cover AHU-level certification.
- Removable Coils and Coil Pull DesignExplains coil rack, side-pull and track designs for future coil replacement; room space planning is in fundamentals.
- Low-GWP A2L Refrigerants and DX Coil DesignExplains how R-454B and R-32 affect DX coil design and leak detection in AHUs; refrigerant safety code requirements are in codes.
- Stacked Coils and Intermediate Drain PansExplains when coils must be stacked and how intermediate pans prevent carryover; main drain pan design is in casing.
how tos
- How to Select a Chilled Water CoilSteps from entering conditions and capacity to rows, fins, circuiting and delta-T; does not cover DX coils.
- How to Design Coil Connections for CounterflowHow to orient supply and return headers for counterflow and same-end connections at design stage; field hookup kits are not covered.
- How to Vent and Drain Water CoilsSteps and hardware for venting air and draining coils for winterization; freeze protection strategies are separate.
- How to Place and Size Preheat Coils for High Outdoor AirSteps to locate and size preheat coils for 100% OA and cold climates; does not compare freeze protection methods.
comparisons
- More Rows vs Higher Fin Density: Coil TradeoffsCompares adding rows or fins for capacity against air pressure drop and cleanability; does not cover materials.
- Steam Distributing Coils vs Standard Steam CoilsCompares tube-in-tube distributing and standard steam coils for freeze resistance and uniformity; does not cover steam trapping.
- Coil Materials: Copper, Aluminum, Stainless and Cu-NiCompares tube and fin material combinations for heat transfer and corrosion; applied coatings are a separate guide.
- Open Coil vs Finned Tubular Electric HeatersCompares electric heater element types for safety, pressure drop and airflow requirements; does not cover SCR control.
- Face and Bypass Dampers vs Integral Face-and-Bypass CoilsCompares separate face and bypass damper arrangements with IFB coils; does not cover other freeze methods.
calculations
- Sizing a Hot Water Heating CoilCalculates capacity, water flow and leaving temperatures for heating coils including low-temperature water; does not cover glycol derating.
- Calculating Coil Air-Side Pressure Drop, Dry and WetCalculates air-side pressure drop for dry and wet coils by rows and fins; does not cover water-side drop.
- Coil Tube Velocity, Turbulence and Water Pressure DropCalculates tube velocity and water-side pressure drop and why turbulent flow matters; does not cover glycol effects.
- Calculating Glycol Effects on Coil Capacity and Pressure DropCalculates capacity loss and pressure drop increase with ethylene and propylene glycol; does not cover freeze protection strategy.
troubleshootings
- Troubleshooting Low Delta-T in Chilled Water CoilsDiagnoses causes of low coil delta-T such as fouling, valve problems and setpoints; does not cover coil capacity shortfall.
- Diagnosing a Coil That Is Short on CapacityDiagnoses airflow, water flow, air binding and fouling causes of low capacity; does not cover low delta-T.