AHU Fundamentals
Core concepts, configurations and air-side calculations behind every air handling unit.
explainers
- What Is an Air Handling Unit? Sections and Airflow PathDefines a central-station AHU and walks the airflow path through its standard sections; does not cover sizing, selection or any one application.
- How the Mixing Box and Economizer Section WorksExplains damper arrangement, mixing geometry and air blenders in the mixing section; control sequences for economizers are covered in the controls category.
- 100% Outdoor Air Handling Units: Design ConsiderationsExplains what changes when an AHU handles only outdoor air (preheat, wide load swings, latent load); does not cover DOAS versus RTU system choice.
- Internal vs External Static Pressure ExplainedDefines ISP, ESP and TSP and where each is measured on a unit; does not tabulate component pressure drops (see the static pressure budget guide).
- Dual-Path and Dual-Duct AHU ArrangementsExplains separate outdoor-air and return-air paths, hot/cold deck dual-duct units and when each is used; does not cover multizone dampers in controls.
- AHU Terminology Glossary for Engineers and OwnersDefines common air handling terms from bhp to TSP in plain language; does not provide design procedures.
- Sensible Heat Ratio and Why It Shapes AHU DesignExplains SHR, room vs coil SHR and how a low SHR drives coil and reheat decisions; does not size dehumidification equipment.
- AHU Turndown: How Low Can Airflow Go?Explains limits on minimum airflow set by fans, coils, filters and outdoor air control; does not provide VAV reset sequences.
comparisons
- AHU vs Packaged Rooftop Unit vs DOAS: Choosing a System TypeCompares custom AHUs, packaged RTUs and dedicated outdoor air systems at the system-type decision level; does not compare individual components or brands.
- Draw-Through vs Blow-Through Fan Position Relative to the CoilCompares fan placement upstream or downstream of the cooling coil and its effect on fan heat, leaving-air condition and coil uniformity; does not cover fan type selection.
- Horizontal, Vertical and Stacked AHU ConfigurationsCompares unit footprint arrangements (inline horizontal, vertical, stacked/double-deck) for mechanical room fit; does not cover casing construction details.
- Constant Volume vs VAV Air HandlersCompares single-zone constant volume, single-zone VAV and multizone VAV AHU types and their duty; does not cover VAV control sequences.
- Return Fan vs Relief Fan: Choosing the ArrangementCompares return-fan and relief-fan hardware arrangements and their pressure profiles; pressurization control sequences are covered separately.
- Indoor vs Outdoor (Weatherproof) Air Handling UnitsCompares locating the AHU indoors or outdoors for cost, service and envelope impacts; weatherproofing construction details are in the casing category.
how tos
- How to Plot AHU Processes on a Psychrometric ChartStep-by-step plotting of mixing, cooling, reheat and humidification processes for an AHU; does not explain humidity control equipment choices.
- How to Order AHU Sections: Standard Component SequenceExplains how to sequence dampers, filters, coils, fans, humidifiers and attenuators and why; does not size any component.
- Selecting Outdoor Design Conditions From ASHRAE Climate DataHow to choose 0.4%, 1% and dew-point design values for US and Canadian locations when sizing an AHU; does not cover load calculation methods.
calculations
- Calculating Supply Airflow From Sensible LoadWorks the 1.08 x cfm x delta-T relationship with altitude correction to size supply airflow; does not cover static pressure or fan selection.
- Building a Total Static Pressure Budget for an AHUTabulates component pressure drops plus external system losses to arrive at fan total static; does not cover selecting the fan itself.
- Sizing an AHU Cross-Section From Face Velocity TargetsCalculates unit width and height from the governing component's face velocity limit; coil moisture carryover limits are covered in the coils category.
- Calculating Fan and Motor Heat Gain in the AirstreamCalculates the supply temperature rise from fan and motor heat including motor-in-airstream cases; does not compare fan positions.
- Calculating Mixed-Air Temperature and HumidityWorks the mass-weighted mixing calculation for temperature and humidity ratio; does not address physical stratification in the plenum.
checklists
- When to Add Access Sections: A Serviceability ChecklistChecklist of where access, plenum and blank sections are needed for inspection and cleaning; does not cover door hardware specification.
- Mechanical Room Planning Checklist for AHUsSchematic-design checklist for room size, coil pull space, door paths and duct exits; does not cover rigging or setting the unit.